Search results for "Alveolar Bone Loss"
showing 10 items of 67 documents
Satisfaction and quality of life with palatal positioned implants in severely atrophic maxillae versus conventional implants supporting fixed full-ar…
2015
Background: To evaluate satisfaction and quality of life in patients with palatal positioned implants supporting fixed full-arch prostheses to rehabilitate edentulous maxillae with horizontal atrophy and compare them with conventional well-centered implants placed in non-atrophic supporting fixed full-arch prostheses. Material and Methods: A clinical retrospective study was performed of patients that were rehabilitated with full- arch fixed implant-supported maxillary prostheses and had a minimum follow-up of 5 years after implant loading. Patients were divided into 2 groups: patients with class IV maxilla according to Cawood and Howell and treated with palatal positioned implants (test) an…
Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
2011
Objectives: Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. Material and Methods: A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data we…
Immediate and flapless implant insertion and provisionalization using autogenous bone grafts in the esthetic zone: 5-year results.
2017
Objectives As the 2-year results for immediately inserted and provisionalized implants have been reported, it remained an open issue, whether the initially high success rates and the esthetic outcome remain stable for longer observation periods. Therefore, this prospective study examines the 5-year hard and soft tissue changes at implants placed in the anterior maxilla. Material and methods Meanwhile, 37 microthreaded implants were placed in 21 patients into extraction sockets with and without facial bone deficiencies by a flapless approach. Facial gaps and bony defects were grafted with autogenous bone chips. The implants were immediately provisionalized. The primary outcome parameters wer…
Implant treatment in atrophic posterior mandibles: Vertical regeneration with block bone grafts versus implants with 5.5-mm intrabony length
2014
Purpose: To retrospectively compare the outcomes of implants placed in posterior mandibles vertically regenerated with onlay autogenous block bone grafts and short dental implants. Materials and Methods: Consecutive patients with vertical bone atrophy in edentulous mandibular posterior regions (7 to 8 mm of bone above the inferior alveolar nerve) were treated with either implants placed in regenerated bone using autologous block bone grafts (group 1) or short implants (with 5.5-mm intrabony length) in native bone (group 2) between 2005 and 2010 and followed for 12 months after loading. The procedure used was the established treatment protocol for this type of patient at the Oral Surgery Uni…
Clinical and radiographic performance of self‐locking conical connection implants in the posterior mandible: Five‐year results of a two‐centre prospe…
2021
Abstract Objective This prospective study aims to assess the 5‐year clinical performance of implants with internal conical connection and platform‐switched abutments in the posterior mandible. Material and Methods Healthy adults missing at least two teeth in the posterior mandible and with a natural tooth mesial to the implant site received two or three adjacent implants. After a transmucosal healing period single crown restorations were cemented on platform‐switched abutments. Changes in marginal bone levels were investigated in standardized periapical radiographs from surgery and loading (baseline) to 60‐months post‐loading. Results Twenty‐four patients received 52 implants. Bone remodell…
Effect of bone loss on the fracture resistance of narrow dental implants after implantoplasty. An in vitro study
2021
Background Implantoplasty (IP) involves polishing of the exposed surface of implants affected by peri-implantitis (PI). A study was made to determine whether the degree of bone loss influences the fracture resistance of implants with or without IP. Material and Methods An in vitro study was carried out on 32 narrow (3.5 mm) dental implants with a rough surface and external hexagonal connection. Implantoplasty was performed in half of the implants of the sample. Both the IP and control implants were divided into two subgroups according to the amount of bone loss (3 mm or 7.5 mm). Standardized radiographic assessment of implant width was performed using specific software. The main outcome var…
Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series
2016
Background: The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods: A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and…
Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review
2020
Purpose: to assess any differences on marginal bone loss between bone-level or tissue-level dental implants through a review of literature until September 2019. Materials and methods: MEDLINE, Embase and other database were searched by two independent authors. The search was limited to articles in English. Results: The search provided 1028 records and, after removing the duplicates through titles and abstracts screening, 45 full-text articles were assessed for eligibility. For qualitative analysis 20 articles were included, 17 articles of them for quantitative analysis. A total of 1161 patients (mean age 54,4 years) and 2933 implants were observed, 1427 (Tissue-level) and 1506 (Bone-level).…
Implant Abutment Cleaning by Plasma of Argon: 5-Year Follow-Up of a Randomized Controlled Trial.
2015
Contamination of implant abutments could potentially influence the peri-implant tissue inflammatory response. The aim of the present study is to assess the radiographic bone changes around customized, platform-switched abutments placed according to the "one-abutment-one-time" protocol, with and without plasma of argon cleaning treatment.Thirty healthy patients with thin gingival biotype (1 mm) and history of periodontal disease received one maxillary implant each. Immediately before abutment connection, patients were randomly assigned to control group (cleaning protocol by steaming) or test group (plasma of argon treatment). Outcome measures were: 1) success rate of implants and prostheses;…
Impact of abutment geometry on early implant marginal bone loss. A double‐blind, randomized, 6‐month clinical trial
2022
Objectives The objective of this study was to analyze the impact of the abutment width on early marginal bone loss (MBL). Material and Methods A balanced, randomized, double-blind clinical trial with two parallel experimental arms was conducted without a control group. The arms were “cylindrical” abutment and “concave” abutment. Eighty hexagonal internal connection implants, each with a diameter of 4 × 10 mm, were placed in healed mature bone. The main variable was the peri-implant tissue stability, which was measured as MBL at 8 weeks and 6 months. Results The final sample consisted of 77 implants that were placed in 25 patients. 38 (49.4%) were placed using the cylindrical abutment, and t…